System Architecture
Ports
- 2 Gbit/sec Fibre Channel (auto-sensing); supports E_Port and F_Port
WAN ports
- 1 Gbit/sec Ethernet (with compression); OC-3 ATM (with compression); 10/100 Ethernet (with compression)
Classes of service
Management access
- RS-232; 10/100 Ethernet (RJ-45)
Warranty
Physical Specifications
Enclosure
- 1U rack-mountable or tabletop (allow clearance for maintenance and cable access)
Height
Width
Depth
Weight
Operating temperature
- 40° to 104°F (5° to 40°C)
Humidity
- 5 to 90% (non-condensing)
Input power requirements
- 90–240 VAC, 47–63 Hz, 2.5 Amps
Airflow
Heat dissipation
Fibre Channel Specifications
Designed to meet FCIP, FC, FC-2, and FC-BB-2 standards/emerging standards
Cable type
Core diameter
- 62.5 microns and 50 microns
Cladding diameter
Numerical aperture
Attenuation (max.)
- 1.5 dB/km at 1300 nm
- 3.75 dB/km at 850 nm
Operational wavelength
Bandwidth (min.)
Fiber count
Maximum length
- 50 microns = 500 meters at 100 MB/sec
- 50 microns = 300 meters at 200 MB/sec
- 62.5 microns = 250 meters at 100 MB/sec
- 62.5 microns = 120 meters at 200 MB/sec
Connector type
Gigabit Ethernet Specifications
Supports full-duplex Ethernet on each port and is designed
to meet these standards:
- IEEE 802.3z/802.3ab Gigabit Ethernet Standard
- IEEE 802.3x flow control
- IEEE 802.1p packet priority
Cable types
- Multimode, single-mode, and CAT5 UTP
Ethernet 10/100 Specifications
- Supports IEEE 802.3 and ANSI 8802-3 Ethernet 10/100 standards; uses CAT5 UTP cable
OC-3 ATM Specifications
Designed to meet the following standards:
- ATM Forum UNI 3.0 and 3.1
- ATM Forum AAL-5
- ATM Forum UBR, VBR, and CBR
- ATM Forum af-phy-0062.000
- ITU Recommendation I.432
- ITU Recommendation G.704, G.704, G.707
ATM Physical Characteristics
|
| |
Optical multimode |
Optical single-mode |
|
| Core diameter |
50 or 62.5 microns |
9 microns |
|
| Cladding diameter |
125 microns |
125 microns |
|
| Bandwidth |
Up to 155 Mbps |
Up to 155 Mbps |
|
| Reach |
2 km |
40 km |
|
| Connector type |
Duplex LC |
Duplex LC |
|
Regulatory Compliance
- FCC/EMC
- Conforms with FCC Part 15 Class A subpart J, (U.S.A) EN55022 Class A, EN55024, 1998, EN61000-3-2/3
- Safety: CUL 1950, EN6950 – IEC950
|
|