Brocade 5300 Switch带有FICON t.的4、8和10 Gbit/sec光纤通道导向器。在一个域内不停机地从32个扩展到384个同时活动的4或8 Gbit/sec全双工端口。行业领先的功率和冷却效率。高可用性、多协议连接。

联系我们了解更多博科产品。






Systems Architecture

System Blades

  • Up to 384 4 or 8 Gbit/sec Fibre Channel ports; up to eight Fibre Channel blades (16, 32, or 48 ports per blade); up to 1152 ports per 42U rack
  • Up to eight Brocade FC10-6 blades (six 10 Gbit/sec Fibre Channel ports per blade)
  • Up to four Brocade FR4-18i SAN Extension blades (16 4 Gbit/sec Fibre Channel ports and two Gigabit Ethernet ports per blade)
  • Up to four Brocade FC4-16IP iSCSI blades (eight 4 Gbit/sec Fibre Channel ports and eight Gigabit Ethernet ports per blade)
  • Up to two Brocade FA4-18 Application Blades (16 4 Gbit/sec Fibre Channel ports and two Gigabit Ethernet ports per blade)

Control Processor

  • Redundant (active/standby) control processor modules

Scalability

  • Full fabric architecture of 239 switches maximum

Certified Maximum

  • Single Brocade FOS fabric: 56 domains, 19 hops, 6000 ports
  • Single Brocade M-EOS fabric: 31 domains, three hops
  • Larger fabrics certified as required; consult Brocade or OEM SAN design documents for configuration details

Port Rates

  • 1.063 Gbit/sec line speed, full duplex; 2.125 Gbit/sec line speed, full duplex; 4.25 Gbit/sec line speed, full duplex; auto-sensing of 1, 2, and 4 Gbit/sec port speeds; optionally programmable to fixed port speed; speed-matching between 1, 2, and 4 Gbit/sec ports and between 2, 4, and 8 Gbit/sec ports; 10.5 Gbit/sec line speed, full duplex, fixed port speed

ISL Trunking

  • Up to eight ports per ISL trunk, delivering up to 64 Gbit/sec per ISL trunk using 8 Gbit/sec ports. Trunking is not supported with the FC10-6 (10 Gbit/sec) blade.

System Bandwidth

  • 1024 Gbit/sec backplane switching capacity
  • 3.264 Tbit/sec (4 Gbit/sec blades, local switching)
  • 6.528 Tbit/sec (8 Gbit/sec blades, local switching)

Switch Latency

  • <2.1 μsec any port to any port at 2 Gbit/sec, cut-through routing; <3.6 μsec any port to any port at 4 Gbit/sec, cut-through routing; <7.4 μsec any port to any port at 10 Gbit/sec, cut-through routing

Maximum frame size

  • 2112-byte payload

Frame Buffers

  • 1000 for FC4-16, FR4-18i, FC4-16IP; 2000 for FC4-32, FC4-48; dynamically allocated up to 255 per port; 2000 for FC8-16, FC8-32, and FC8-48 with up to 1500 per port; 720 for FC10-6

Classes of Service

  • Class 2, Class 3, Class F (inter-switch frames)

Port Types

  • FL_Port (all except on FC4-48 and FC10-6 blades), F_Port (including NPIV support), E_Port, self-discovery based on switch type (U_Port); port type control for EX_Port, VE_Port and Vex_Port; Gigabit Ethernet for VE_Port and Vex_Port; FC10-6 supports E_Port only

Data Traffic Types

  • Fabric switches supporting unicast, multicast (255 groups), and broadcast

Media Types

  • Hot-pluggable, industry-standard Small Form-Factor Pluggable (SFP), LC connector; Short-Wavelength (SWL) up to 500 meters (1640 feet); Long-Wavelength (LWL) up to 10 km (6.2 mi); FC10-6 blade also supports Extended Long-Wavelength (ELWL) up to 80 km (49.6 mi); distance depends on fiber-optic cable and port speed, CWDM SFPs (8 lambdas)

Fabric Services

  • Adaptive Networking Services: traffic isolation, ingress rate limiting (for FC8 blades only); Simple Name Server; Registered State Change Notification (RSCN); Alias Server (multicast); Brocade Advanced Zoning, Web Tools, Fabric Watch, Extended Fabrics, ISL Trunking, DPS, and Advanced Performance Monitoring

System Security

  • FIPS 140-2 L2 Certifiable; management access security (RADIUS); Active Directory with LDAP

High Availability

Chassis Power

  • Two ACAC-DCDC power supply modules, each delivering 1000 W DC, 2N redundancy; with Brocade FA4-18, FR4-18i, FC10-6, and FC4-16IP blades four AC-DC power supply modules are required for full redundancy

Cooling

  • Three blower assembly modules (two operational required)

Solution Availability

  • Designed to provide 99.999 percent uptime capabilities to meet the highest availability standards
  • Hot-pluggable redundant power supplies, fans, processors, port blades, and optics; online diagnostics; non-disruptive firmware download and activation

Management

Management Capabilities

  • Fabric Manager; EFCM; Telnet; SNMP (FE MIB, FC Management MIB); FICON/CUP on FC4 and FC8 (16- and 32-port) blades, Web Tools; third-party applications utilizing the Brocade SMI Agent

Management Access

  • 10/100 Ethernet (RJ-45), in-band over Fibre Channel (requires fabric); two serial ports (DB-9) per control processor module

Mechanical Specifications

Enclosure

  • Rear panel-to-door airflow

Width

  • 43.74 cm (17.22 in)

Height

  • 61.24 cm (24.11 in) for 14U

Depth

  • 70.90 cm (27.90 in) without door
  • 74.20 cm (29.20 in) with door

System weight

  • 95 kg (210 lb) for 128-port configuration (eight 16-port blades, without media)
  • 98 kg (216 lb) for:
    • 256-port configuration (eight 32-port blades, without media)
    • 384-port configuration (eight 48-port blades, without media)
    • 48-port configuration (eight 6-port blades, without media)

Environment

Temperature

  • Operating: 0° C to 40° C (32° F to 104° F)
  • Non-operating: –25° C to 70° C (–13° F to 158° F)

Humidity

  • Operating: 5% to 85% non-condensing at 40° C (104° F)
  • Non-operating and storage (non-condensing): 0% to 93%

Altitude

  • Up to 3000 meters (9800 feet)

Shock

  • Operating: 20G, 11 ms, half sine 1G p-p, 5–500Hz, 1 octave min
  • Non-operating: 33G, 11 ms, half sine 2.4G p-p, 5–500Hz, 1 octave min

Vibration

  • Operating: 5G p-p, 0 to 3 kHz at 1.0 octave min
  • Non-operating: 10G p-p, 0 to 5 kHz at 1.0 octave min

Heat Dissipation

  • 710 W or 2425 BTU (525 W DC internal draw) to 1681 W or 5832 BTU (1261 W DC internal draw), subject to blade type

CO2 Emissions

  • 4,990 kg per year

Power
Supported Power Range

  • Nominal: 200 to 240 VACAC nominal, 5.0 A, single phase
  • Operating: 180 to 264 VACAC auto-sensing

Note: 256-port configuration requires a maximum of 750 Volt-Amps

In-Rush Current

  • 40 Amps maximum, peak

Frequency

  • 47 to 63 Hz
Regulatory Compliance
Canada CSA 60950 ICES 003 Class A
United States UL 60950 FCC Part 15 Class A
Japan IEC60950 VCCI Class A ITE
European Community EN60950 EN55022 Level A
TUV, NEMKO EN55024
Korea RRL
Russia GOST GOST
Australia/New Zealand AS/NZS 3548 Class A
 

产品资源库

有全部博科资源库可供浏览,请点击中文资源库 , 英文资源库

虚拟化、富多媒体应用程序以及对高效、低成本的追求,正在驱动新一波网络升级。实施这类项目时,首席信息官需要确定最重要因素,以便构建快速、高度可靠、更易管理和成本更低的网络基础架构。
Brocade M6140 Director是支持24X7关键业务环境的最佳选择。在存储网络核心采用4-Gbit/sec和10-Gbit/sec博科公司导向器,就可以满足存储的指数性增长需求,并可以进一步扩展,满足企业中预料之外的调整需求。
当今企业SAN的发展规模正在呈指数性增长,为了有效的降低成本并充分利用存储设备,企业必须融合和简化庞大的、多元化的存储网络环境。Brocade Mi10K Director堪当此任,为企业环境带来功能完善、灵活可行的解决方案。通过Brocade Mi10K,企业可以安全有效地融合大型、异构且分布于自夸地的存储区域网络。Brocade Mi10K在一个紧凑的14U高的机箱中,提供高达256个1/2/4和10Gbit/sec I/O端口,它是当今业界性能最高的SAN交换机设备。
Brocade 48000导向器为企业级SAN带来了业界领先的4、8、10Gbit/sec光纤通道连接能力、高可用性、多协议连接和全面的投资保护。它可以不停机的从32个端口扩展到一个域中的多达384个同时激活的4或8Gbit/sec全双工端口。此外,它还支持光纤通道路由、FCIP和iSCSI,并用于支持广泛的Fabric应用。Brocade 48000还提供业界领先的能耗和盗运效率,帮助降低总体拥有成本。